Overview
WBU stores with EP 1.0.X installed applications are not able to process CC transactions.
Processor: TSYS
+Root element error
+There was no endpoint listening at https://dev_liq.dev.cloudretailer.com/RiteAutoUpdate/AutoUpdateService.svc that could accept the message.
Procedure
- Install EP 2.0.7
- Check if you can log in to EP Interface (If not, rename settings.xml then try again)
- Check if you can initialize CC terminals
- if not, you might need to change the CC terminal's LAN type to DHCP -it requires PWD use the default password 7724629)
- Refer steps To change LAN type (Static to DHCP) - PAX S300
- Refer steps To change LAN type (Static to DHCP) - PAX S300
- Ran IP Scanner to check the current Ip address assigned to the CC then update it in EP and initialize.
- if not, you might need to change the CC terminal's LAN type to DHCP -it requires PWD use the default password 7724629)
- Ask the client to do a test CC transactions
----
PAX S300
To change LAN type (Static to DHCP)
FN (Blue button+1)
Select Comm settings
Select Lan Parameters
Select Lan type (Static | DHCP)
Press enter it goes to the IP:
Press enter it goes to netmask
Press enter it goes to gateway
Press enter it goes to DNS
References
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article